Ionized vs Photoelectric Smoke Detectors

2Gig Smoke Detector

Overview

The monitored smoke detector offers life-saving protection from fire.  As a life-saving device particular attention should be made when determining the best location for the sensor.  

The Smke3 is a photoelectric smoke detector, meaning it detects the larger, darker types of smoke from burning plastic, sheetrock, and other engineered types of materials.  Photoelectric smoke detectors detect a home fire (on average) by several MINUTES faster than the common smoke detectors found in homes. 

A 2nd and 3rd zone can (should) be programmed to detect Heat and Freeze.  

Note:  DO NOT install in commercial accounts.

2gig-smkt3-345-wireless-smoke-heat-and-f

Specifications

  • Transmits at a frequency of 345 Mhz

  • Signal range of 350 ft (open air)

  • Temperature range of 40 - 100 degrees F

  • Requires 3 X AAA lithium battery

  • Typical battery life of 5 years

  • Sensor life is 5 years from manufacture date; at that time it should be replaced.

Installation

Height: ​

  • Should be ceiling mounted, if possible.  Should be 12" from any wall​

  • If wall mounted, should be at least 6" from the ceiling

​Ideal Locations:

  • In each sleeping area, and/or directly outside the sleeping areas

  • On each floor of the home, close to the stairs leading to the floor above

DO NOT Install in these locations:

  • Directly above a sink, stove, or oven

  • Within 5' of any cooking appliance

  • Next to windows, doors, air vents, return air intakes, or other highly ventilated spaces

  • In or below cupboards

  • Highly dusty areas where the sensor can get clogged

  • Where it can be bumped and damaged

Installation steps

  1. Remove device and battery from packaging.

  2. Insert battery.

  3. Attach bracket to wall or ceiling using 2 drywall screws or provided anchors and screws.

  4. Mount sensor to backplate.

Programming

  1. Enter Zone Programming and select the zone you wish to program the sensor into

  2. Tap Edit Zone

  3. Select sensor type (Type 09, 24 hr Fire)

  4. Select the equipment code (Smke3)

  5. Type in the TXID serial number, or select Learn and then tamper the smoke detector by twisting the sensor counter-clockwise and slightly removing from the backplate, then reattaching.

  6. Under Equipment Age select New (do NOT use existing smoke detectors)

  7. Choose an appropriate voice descriptor.

To program the heat and freeze detectors:

  1. Select new zone

  2. For Heat detector use Type 09; For Freeze use Type 08, and select equipment type as Temperature

  3. Use Loop 2 for Heat, Loop 3 for Freeze

  4. Program Serial Number

  5. Program both as Existing for equipment age 

2GSD_Battery_3.jpg
smoke diagram.png
smoke diagram.png