Overview
The monitored smoke detector offers life-saving protection from fire. As a life-saving device particular attention should be made when determining the best location for the sensor.
The Smke3 is a photoelectric smoke detector, meaning it detects the larger, darker types of smoke from burning plastic, sheetrock, and other engineered types of materials. Photoelectric smoke detectors detect a home fire (on average) by several MINUTES faster than the common smoke detectors found in homes.
A 2nd and 3rd zone can (should) be programmed to detect Heat and Freeze.
Note: DO NOT install in commercial accounts.

Specifications
-
Transmits at a frequency of 345 Mhz
-
Signal range of 350 ft (open air)
-
Temperature range of 40 - 100 degrees F
-
Requires 3 X AAA lithium battery
-
Typical battery life of 5 years
-
Sensor life is 5 years from manufacture date; at that time it should be replaced.
Installation
Height:
-
Should be ceiling mounted, if possible. Should be 12" from any wall
-
If wall mounted, should be at least 6" from the ceiling
Ideal Locations:
-
In each sleeping area, and/or directly outside the sleeping areas
-
On each floor of the home, close to the stairs leading to the floor above
DO NOT Install in these locations:
-
Directly above a sink, stove, or oven
-
Within 5' of any cooking appliance
-
Next to windows, doors, air vents, return air intakes, or other highly ventilated spaces
-
In or below cupboards
-
Highly dusty areas where the sensor can get clogged
-
Where it can be bumped and damaged
Installation steps
-
Remove device and battery from packaging.
-
Insert battery.
-
Attach bracket to wall or ceiling using 2 drywall screws or provided anchors and screws.
-
Mount sensor to backplate.
Programming
-
Enter Zone Programming and select the zone you wish to program the sensor into
-
Tap Edit Zone
-
Select sensor type (Type 09, 24 hr Fire)
-
Select the equipment code (Smke3)
-
Type in the TXID serial number, or select Learn and then tamper the smoke detector by twisting the sensor counter-clockwise and slightly removing from the backplate, then reattaching.
-
Under Equipment Age select New (do NOT use existing smoke detectors)
-
Choose an appropriate voice descriptor.
To program the heat and freeze detectors:
-
Select new zone
-
For Heat detector use Type 09; For Freeze use Type 08, and select equipment type as Temperature
-
Use Loop 2 for Heat, Loop 3 for Freeze
-
Program Serial Number
-
Program both as Existing for equipment age